Backflow is the flow of water in a reverse direction. This can be especially troublesome for plumbing systems that are dealing with sewage or contaminated wastewater. When this water "backflows" through a pipe it can contaminate a water supply. To prevent this from happening federal law requires the installation of a backflow prevention device in any situations where backflow is possible. This would include backflow from irrigation and sprinkler systems, fire suppression lines, beverage machines, sewer lines, water mains, and more. These devices must also be tested at least once per year by a professional plumber to ensure they are still working correctly.
We service the following types of Backflow Prevention Devices:

A pressure vacuum breaker contains:
Under normal water pressure:
If supply pressure drops or a vacuum condition occurs:

An SVB contains:
During normal operation:
If a vacuum or negative pressure condition occurs:

A double check assembly contains:
Water flows in one direction through both check valves. If water pressure reverses, the check valves close to prevent contaminated water from flowing backward into the clean water supply.
Unlike an RP assembly, a DC assembly does not have a relief valve.

An RP backflow preventer contains:
The device maintains a pressure zone between the two check valves that is lower than the supply pressure. If either check valve fails or pressure reverses, the relief valve opens and discharges water to prevent contaminated water from flowing back into the potable water supply.
Copyright © 2026 backflow testing - All Rights Reserved.
We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.